Introduction | Features | Part Numbers | Dimensions
Introduction
- Metal Shell Wire Wrap connectors are available with .025″ sq. or .045″ sq. x 1.35″ (.56″ wrap length) terminals. .045″ sq. terminals are also available with .850″ (.28″ wrap length) terminals.
- Available with .103″ mounting holes for #3 hardware. Sockets also available with bail latches and .116″ holes
Back to Top
Features
Terminates Discrete Wire without soldering, on .025″ sq. or .045″ sq. tails.
- Available in 50 position.
- All plugs lock with InstaLatch passive latch feature for automatic latching. Sockets available with InstaLatches where indicated.
- Available with industry-standard bail latch feature for positive locking/unlocking without tools.
- UL Recognized – Files E170218 (UL1977), E130965 (UL1863).
- CSA Approved – File LR31996-7.
Materials
- Insulator (Metal Shell Product): Blue UL94V-0 rated dialyll phthalate type MDG per MIL-M14F
- Insulator (All-Plastic Product): Gray UL94V-0 rated dialyll phthalate type MDG per MIL-M14F
- Contact: Copper alloy
- Contact Plating: Select gold over 50µin. select nickel standard. 30µin. select gold over 50µin. select nickel available where indicated
- Wire-Wrap Terminal: Cupro nickel
- Shell: Steel
- Shell Plating: Zinc with clear chromate coating
Mechanical
- Durability: 200 mating/unmating cycles
- Mating / Unmating Forces:
| |
Mating Force (max.) |
|
Unmating Force (min.) |
| |
with InstaLatches |
|
without InstaLatches |
| Size |
Lb. |
Kg |
|
Lb. |
Kg |
| 50 |
32 |
14.52 |
|
7 |
3.18 |
Electrical
- Voltage Rating: 500 VAC @ sea level; 125 VAC @ 70,000 ft.
- Withstanding Voltage: 1200 VAC RMS @ sea level, per EIA Std. RS364, TP20
- Contact Rating: 5 Amps (4 Amps per CSA)
- Contact Resistance: 6 milliohms maximum, per EIA Std. RS364, TP6
- Insulation Resistance: 5000 Megohms minimum initial. 1000 Megohms minimum after moisture
Environmental
- Operating Temperature: -40°C to +105°C
- Shock: 50G Peak, per EIA Std. RS364, TP27, Condition A
- Vibration: 3 cycles @ 10-55Hz in each of 3 axes per EIA Std. 364, TP28, condition A
- Moisture Resistance: Per EIA Std. RS364, TP31, Condition B, with step 7B excluded
back to top
Part Numbers
Click on any part number to see it’s current stock with our distributors.
Plug, InstaLatching
Socket
back to top
Dimensions

| |
A |
B |
C |
D |
| Sizes |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 50 |
3.260 |
82.80 |
2.947 |
74.85 |
2.240 |
56.90 |
2.040 |
51.82 |
|